Estimates only. Conventional fans are taken at 75 W each and HVLS fans at 65% of rated motor load, which is typical at normal operating speed. Leave the existing fan count blank and we assume one conventional fan per 150 sq.ft. Enter a budget figure to see a payback period, or request a quote for the real number.

Worked Example

A 15,000 Sq.Ft. Facility, Worked Through

A single-bay shed with a 26 ft roof, running twelve hours a day, twenty-six days a month, at ₹8.50 per unit — replacing ninety wall mounted circulators.

Worked ROI example for a 15,000 sq.ft. facility
Parameter Existing Conventional Fans Austar HVLS
Fan Quantity 90 units 1 × AS245 (24 ft)
Power Per Unit 75 W 1.5 KW rated, ~0.98 KW running
Connected Load 6.75 KW 0.98 KW
Running Hours / Month 312 hours 312 hours
Units Consumed / Month 2,106 units 304 units
Cost / Month @ ₹8.50 ₹17,901 ₹2,584
Saving Per Hour ₹49 per running hour
Saving Per Month ₹15,317
Saving Per Year ₹1,83,804
Maintenance Points 90 1
Floor Space Freed All pedestal positions

Illustrative. Actual figures depend on your tariff, running pattern, roof height and what is being replaced — which is exactly what the calculator above is for.