Geared
ASGL206 — 20 Feet Gearless HVLS Fan
20 Feet · Gearless
- Diameter
- 20 ft
- Blades
- 6
- Air Delivery
- 410,000
- Motor
- 1.2 KW
- Coverage
- 16,000 ft²
- Noise
- Below 40 dB
ASGL206 — Gearless 20 Feet HVLS Fan
The ASGL206 is the large-bay direct drive fan, and the first in the range to move to a three phase supply. A direct driven PMSM outer rotor motor, air and liquid cooled and made in India, is rated 1.2 KW at 270 Nm and turns the 20 ft sweep (6.1 m) at anything from zero to 50 rpm, moving 410,000 CFM. The motor runs N45SH grade magnets, Class H insulation and aluminium top and bottom plates rather than sheet metal. Six cambered aerofoil blades are rolled in Aluminium 6063 T6 to a 190 mm section with two ribs. Supply is three phase 415 V, 50 Hz, and the fan weighs about 125 kg. Noise stays below 40 dB, which is what puts this range into showrooms, halls and food and pharma floors.
What Comes With It
- Direct driven PMSM outer rotor motor, air and liquid cooled, made in India — 1.2 KW, 270 Nm, no gearbox and no gear oil
- N45SH magnets, Class H insulation, aluminium top and bottom plates (no sheet metal)
- Six cambered aerofoil blades in Aluminium 6063 T6, 190 mm section, two ribs
- Laser cut M.S. mounting structure and motor mounting bracket, minimum 8 mm plate
- 3" square extension tube of reputed make — Asian, Apollo or Surya
- High tensile 10.9 grade HEX bolts, Unbrako or TVS make, with self-locking Nyloc nuts
- Delta VFD in an IP54 powder coated steel cabinet — start and stop on green and red display, speed adjustment, emergency stop, and a display for speed and status parameters
- BMS compatible control interface
- Input power three phase 415 V, 50 Hz
- Matt Black, Silver, Pure White or Dark Gray — or any RAL number to order
- Complies with CE requirements
| Model | ASGL206 |
|---|---|
| Diameter | 20 feet (6.1 m) |
| Blade Quantity | 6 |
| Blade Material | Aluminium 6063 T6, cambered aerofoil, 190 mm section, 2 ribs, Matt Black (customisable to RAL) |
| Air Delivery | 410,000 CFM |
| Motor Make & Rating | Direct drive PMSM outer rotor — 1.2 KW, 270 Nm torque |
| Speed Range | 0 – 50 rpm (variable) |
| Noise Level | Below 40 dB |
| Coverage Area | up to 16,000 sq.ft. (indicative, at standard mounting height) |
| Insulation Class | Class H |
| Magnet Grade | N45SH, permanent magnet outer rotor |
| Power Supply | Three phase 415 V, 50 Hz |
| Frame | Laser cut M.S. mounting structure and motor bracket, minimum 8 mm plate; 3" square extension tube (Asian / Apollo / Surya) |
| Hub | Single piece hub with a safety ring interlocking all six blades; die cast aluminium, radiography tested before assembly |
| Fasteners | High tensile 10.9 grade HEX bolts (Unbrako / TVS) with self-locking Nyloc nuts |
| Control Panel | Delta VFD in an IP54 powder coated steel cabinet — start / stop, speed adjustment, emergency stop, BMS compatible |
| IP Rating | IP54 (control panel) |
| Certification | Complies with CE requirements |
| Approx. Weight | 125 kg approx. |
Specifications are subject to continuous improvement. Confirm current values against the model datasheet at the time of order.
Anti-Fall Mounting Bracket
The extension tube, motor and hub assembly hang from an anti-fall mounting bracket, so the assembly is still held even if the motor or extension tube bolts fail.
Single Piece Hub And Safety Ring
A single piece hub carries all six blades, and a safety ring interlocks the blades to each other so no blade is retained by its own fixing alone.
Wire Rope Restraint
Every bolted joint is wrapped with 8 mm diameter wire rope, and four further 8 mm ropes carry the fan in balance.
Bolted Joints
All nuts are self-locking Nyloc type, which eliminates any chance of loosening in service, on high tensile 10.9 grade Unbrako or TVS bolts.
Installation Requirements
- Minimum roof height of 18 ft to the underside of the fan for effective coverage; below that, fan count rises.
- Blade tip clearance of at least 600 mm from any beam, duct, light fitting, sprinkler or crane path.
- Hanging point on a load-bearing truss node or purlin, verified at site survey — not a decorative or false ceiling.
- Delta VFD panel wall mounted 4 to 5 ft from floor level, clear of wash-down, oil and heavy dust zones.
- Input power three phase 415 V, 50 Hz to the VFD panel.
- Access equipment (scissor lift or scaffolding) available at site on the installation date.
What We Handle
Dispatch and site handling, hanging structure fitment, fan assembly and mounting, control panel mounting, VFD commissioning, run testing across the full speed range, and an operator briefing at handover — all by our own qualified technicians.
5 Years
Blades, hub, extension tube and mounting structure — replacement warranty
2 Years
Motor, controller and VFD — replacement warranty
ASGL206 Technical Data Sheet
The signed factory data sheet for this model — every published figure on this page comes from it.
PDF · 1.1 MB · Rev 09
Download Data SheetAustar Company Brochure
Complete company profile, range overview and manufacturing capability.
PDF · 4.2 MB
DownloadGeared Range Brochure
AS125 to AS245 — five geared models with full specification.
PDF · 2.8 MB
DownloadGearless Range Brochure
ASGL086 to ASGL246 — six direct drive models with full specification.
PDF · 2.6 MB
DownloadWhere The ASGL206 Fits
Facility types where this diameter and drive type is a routine specification.
Request A Quote For The ASGL206
The model is already filled in. Add your shed details and we will size the quantity for your floor.